SPM-HEP-5962 is the starter relay: a black sealed box with a mounting flange and a short lead to a white four pin plug. It is used on Doosan DH55, DH60-7, DX27Z. This aftermarket version has the same mounting and electrical connector as the original, so it plugs in and bolts on where the old one came off.
It replaces Doosan K1033657 and Doosan 537-00010.
Technical properties & cross references
Specifications
| Part Type |
Starter Relay |
| Connection |
Flying lead, white four pin plug |
| Condition |
New, aftermarket |
| Stat. HS-Code |
853641 |
| Country of Manufacture |
China |
Compatible equipment
Doosan DH55, DH60-7, DH75, DX27Z and DX30Z excavators
Check the part number on your old unit before ordering.
Cross references
| Brand |
Code |
|
K1033657 |
|
537-00010 |
|
Doosan 537-00010 |
| Spare Part Mart |
SPM-HEP-5962 |
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| Buy Machinery Parts |
USD 51.96 |
7 Nov 2026 |
| eBay, aftermarket seller |
USD 57.42 |
7 Nov 2026 |
| Imara Engineering Supplies |
USD 120.00 |
7 Nov 2026 |
| Spare Part Mart |
USD 30.40 |
Today |
Our price of USD 30.40 is 41% to 75% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
Function dead with good fuses
A starter, glow plug or fuel relay that has burned its contacts stops the circuit without blowing a fuse.
Clicking but no power
A relay that clicks but does not pass current has worn contacts and needs replacing.
Heat and vibration
Relays near the engine wear out from heat and vibration. Swap them during major services.
Fleet spares
Relays are cheap to keep on the van and quick to change on site.
Frequently asked questions
Will it fit my Doosan DH55?
Yes, it was made for the Doosan DH55, and 4 more listed under compatible equipment. Check the old relay is marked K1033657 or one of the cross references, because makers change parts between serial ranges.
How often should I replace the relay on my Doosan DH55?
On the Doosan DH55, there is no fixed interval. It is changed when it fails, and many fail from water in the plug or chafed wiring rather than wear.
What are the signs the relay needs replacing?
A fault code for this circuit, readings that jump or stay fixed, or a part that does not respond with power at the plug.
How do I test the old part first?
Read the fault codes, then check the plug and wiring for corrosion or a broken wire. A wiring fault reads the same as a failed relay.
Do the fault codes need clearing?
Usually. Clear them after fitting and run the machine, so old codes are not mistaken for a new fault.
Is this a genuine Doosan K1033657?
No. It is an aftermarket relay made to replace the Doosan K1033657. It is not made by the original manufacturer; the number only shows what it replaces.