Sullair 88290007-789 is the controller panel for Sullair air compressors. It is the control panel that starts, loads and protects the compressor. This aftermarket version has the same mounting and electrical connector as the original, so it plugs in and bolts on where the old one came off.
Technical properties & cross references
Specifications
| Part Type |
Compressor controller panel |
| Sold as |
1 piece |
| Condition |
New, aftermarket |
| Stat. HS-Code |
853710 |
| Country of Manufacture |
China |
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| eBay (4 aftermarket sellers) |
USD 575.00 to 600.90 |
22 Nov 2026 |
| disenparts.com |
USD 719.98 |
22 Nov 2026 |
| huparts.com |
USD 874.62 |
22 Nov 2026 |
| mymromarts.com |
USD 953.49 |
22 Nov 2026 |
| Spare Part Mart |
USD 485.88 |
Today |
Our price of USD 485.88 is 15% to 49% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
Compressor will not start or shows no display
A failed controller panel shows no display or a fault it cannot clear, so the compressor will not start, load or regulate pressure.
Check before replacing
Check the supply voltage, the fuses and the sensor connections, and read the fault log first.
Fitting tips
Note the settings and parameters before removal, connect every plug to its socket, then set the pressure bands, service timers and machine type to suit the compressor.
Frequently asked questions
Will it replace my original part?
Yes, it is a direct replacement for the original with the same fitting.
How often should I replace it?
There is no fixed interval. It is changed when it fails, and many fail from water in the plug or chafed wiring rather than wear.
What are the signs the controller needs replacing?
A fault code for this circuit, readings that jump or stay fixed, or a part that does not respond with power at the plug.
Should I grease the connector?
A little dielectric grease keeps water out of the plug on machines that work outside. Make sure the terminals are clean and tight first.
How do I test the old part first?
Read the fault codes, then check the plug and wiring for corrosion or a broken wire. A wiring fault reads the same as a failed controller.
Is this a genuine Sullair part?
No. It is an aftermarket controller made to replace the original. It is not made by the original manufacturer; the number only shows what it replaces.