US$25 shipping credit on orders over US$200

Compressed air line filter grades: what DD, PD, AO, AA, X1 and the rest mean

Compressed air line filter grades: what DD, PD, AO, AA, X1 and the rest mean

A compressed air line filter grade is set by the letters in the element's part number, and every maker uses different letters for the same job. Most filter rows have three stages: a general purpose coalescing stage that takes out liquid oil, water and particles, a high efficiency coalescing stage that takes oil aerosol down to around 0.01 mg/m³, and an activated carbon stage that takes out oil vapour. Atlas Copco calls those three DD, PD and QD. Parker domnick hunter calls them AO, AA and ACS. Walker Filtration calls them X1, XA and AC. Read the letters on the old element, find its stage, and order the same stage in the new one.

Below are the grade letters on the brands we stock and how to compare them. For the fitting steps, see how to fit a compressed air line filter element.

Why the grade matters more than the size

We list 3,349 compressed air line filter elements. Across a single maker's range, the elements for one housing size are usually the same diameter and length in every grade, so a general purpose element, a high efficiency element and a carbon element can all slide onto the same filter head. The only reliable difference is the grade code.

Our own spec data shows how different the grades are once they are fitted. These are the clean pressure drops recorded on our listings, grouped by media:

  • Cellulose, 3 µm: 10 mbar (32 elements)
  • Borosilicate glass fibre, 1 µm: 20 mbar (20 elements)
  • Borosilicate glass fibre, 0.1 µm: 50 mbar (44 elements)
  • Activated carbon: 60 mbar (49 elements)
  • Borosilicate glass fibre, 0.01 µm: 80 mbar (57 elements)

The makers rate each grade for one position in the row. Parker states that its AA grade must be preceded by AO, and Atlas Copco says to precede PD+ with DD+. Put a carbon element in the first housing and it meets liquid oil it was never rated for. Walker states that its carbon elements must not run in oil saturated conditions, and Atlas Copco rates its QD+ carbon filter only when it follows a coalescing stage.

Grade letters by brand

Table of compressed air line filter grade letters by brand: pre filter X25, X5, E9, VA; general purpose DD, AO, X1, E7, KB, MA; high efficiency PD, AA, XA, E5, KE, SA; activated carbon QD, ACS, AC, E1, KA, Alup A; dust DDp and PDp, Parker AO and AA in manual drain housings, Kaeser KD.

Figures come from each maker's published data where we could read it, and from our own listing specs for the rest.

  • Atlas Copco: DD is the general purpose coalescing grade and PD the high efficiency grade. Atlas Copco gives a maximum oil carry-over of 0.08 mg/m³ for DD+ and 0.008 mg/m³ for PD+, tested to ISO 8573-2:2018 with 10 mg/m³ of oil at the inlet. QD is activated carbon, rated to 0.003 mg/m³ oil vapour after a DD+ and PD+ pair or a UD+. DDp and PDp are its dust filtration series.
  • Parker domnick hunter (OIL-X): AO is the general purpose coalescing grade, AA the high efficiency grade and ACS the carbon grade. Parker publishes efficiencies of 99.925% for AO and 99.9999% for AA, and states that AA must be preceded by AO. AO and AA elements in a housing with a manual drain are used as dry particulate filters.
  • Walker Filtration: X25 (25 µm) and X5 (5 µm) are pre filters, X1 is the 1 µm general purpose grade, XA the 0.01 µm high efficiency grade and AC the carbon grade. Walker gives maximum oil carry-over of 10, 5, 0.3, 0.01 and 0.003 mg/m³ for those five grades at 20 °C, and colour codes the end caps: X5 green, X1 red, XA blue, X25 and AC black.
  • Hankison: the number after the E is the grade. Grade 9 is a 3 µm coalescer with 5 ppm w/w remaining oil, grade 7 a 1 µm line filter with 1.0 ppm w/w, grade 5 a 0.01 µm high efficiency filter with 0.008 ppm w/w, grade 3 a 0.01 µm grade above it, and grade 1 the carbon vapour grade. So E5-24 is a grade 5 element in size 24.
  • Kaeser: KB is the basic coalescing grade, rated below 0.1 mg/m³, KE the extra coalescing grade, rated below 0.01 mg/m³, KD the dust filter and KA activated carbon. The grade sits at the end of the element code, as in E46KE.
  • Alup and Abac: in our listing data Alup VA elements are 3 µm cellulose, MA elements 0.1 µm glass fibre and SA elements 0.01 µm glass fibre. Abac uses AQFC for 3 µm, AEFC for 0.1 µm, AHFC for 0.01 µm and AFC for carbon.
  • Zander, Ingersoll Rand and SMC: Zander ZP elements are 1 µm and XP elements 0.01 µm in our data. On Ingersoll Rand FA elements, IG is 0.1 µm and IH is 0.01 µm. SMC uses AFF for its 3 µm main line filter, AM for 0.3 µm, AMD, AMH and AME for 0.01 µm grades and AMF for its 0.01 µm grade with activated carbon.

Plain numbers such as Atlas Copco 2255291720 or Kaeser 9.4861.0 carry no grade letter. For those, the grade comes from the cross reference, and our compatibility page lists the cross references for every element we sell.

How to compare grades across brands

Three things make the published numbers hard to line up.

  • Different units. European makers quote oil carry-over in mg/m³. Hankison quotes ppm w/w, tested to the CAGI ADF400 standard at a 100 °F (38 °C) inlet. The two are not the same unit, so a 0.008 ppm figure and a 0.008 mg/m³ figure are not a match.
  • Different test conditions. Walker quotes 20 °C, Parker 21 °C. Parker rates AO with 40 mg/m³ of oil aerosol at the inlet and AA with 10 mg/m³. Atlas Copco rates DD+ and PD+ with 10 mg/m³.
  • Micron is not the whole story. Walker rates its XA grade and its AC grade both at 0.01 µm for particles, yet one is a coalescer and the other is carbon. The particle rating tells you nothing about oil vapour.

The common ground is the ISO 8573-1:2010 air purity class, written as three numbers for particles, water and oil. For total oil, class 1 is up to 0.01 mg/m³, class 2 up to 0.1 mg/m³, class 3 up to 1 mg/m³ and class 4 up to 5 mg/m³. A dash means that column is not covered. Parker gives AO on its own as class 2.-.3 and AO plus AA as class 1.-.2. Atlas Copco gives DD+ as class 2:-:3 and PD+ as class 1:-:2. Walker gives X1 as class 3 for particles and oil and XA as class 1 for both. Match the class and the stage when you cross a grade from one brand to another.

Which order the grades go in

Three filter stages in order: general purpose coalescer, high efficiency coalescer and activated carbon, with Parker ISO 8573-1 classes 2.-.3, 1.-.2 and 1.-.1 after each stage and Atlas Copco oil carry-over of 0.08, 0.008 and 0.003 mg/m3.

The air passes each stage in turn, coarse first. The general purpose coalescer (DD, AO, X1, KB, grade 7, MA) takes out liquid oil, water and particles. The high efficiency coalescer (PD, AA, XA, KE, grade 5, SA) takes oil aerosol down to the 0.01 mg/m³ range. The carbon stage (QD, ACS, AC, KA, grade 1) takes out oil vapour last, once the liquid is gone.

Parker's own figures show what each stage adds. AO alone gives class 2.-.3. AO and AA together give class 1.-.2. AO, AA and ACS together give class 1.-.1.

Dust grades sit outside this order. Atlas Copco lists DDp+ and PDp+ as its dust filtration series, Kaeser has its KD dust grade, and Parker uses AO and AA elements in manual drain housings as dry particulate filters. They are for dry particles, so check which kind the housing was specified for before you order.

Mistakes that put the wrong grade in

  • Ordering by size alone. On Atlas Copco, a DD, PD and QD element for the same housing share the size number: DD60, PD60 and QD60. Order the letters, not just the number.
  • Reading the housing and not the element. Read the grade on the end cap of the element you take out, and check it against the housing label.
  • Treating carbon as a better coalescer. Carbon removes vapour by adsorption. It is not a finer version of the coalescing grade, and it does not belong in the first housing.
  • Using the same change interval for every grade. Atlas Copco gives 8,000 operating hours or one year for DD+ and PD+ elements. Walker gives 12 months or 8,000 hours for its X grades and at least every six months for AC. Hankison gives its grade 1 carbon element a design life of 1,000 hours at rated conditions. Our guide to line filter element service life covers the signs that one is due early.
  • Swapping a coalescer for a dust grade. On Atlas Copco a single lower case p separates them: DD130 and DDp130 are different elements. Read every letter of the code.

Examples from our range

The full range by brand and grade is in our compressed air line filter collection. If the grade code on your element is worn off or does not match any of the above, send us the housing model and any numbers you can read through our quote form and we will identify it.

Frequently asked questions

Is Atlas Copco PD the same grade as Parker AA?
They do the same job in the row. Both are high efficiency coalescing grades that follow a general purpose stage, and both reach class 1 for particles and class 2 for oil: Atlas Copco gives PD+ as class 1:-:2, and Parker gives AO plus AA as class 1.-.2. Match the element dimensions and seal as well as the grade.

Can I fit a high efficiency element in the first housing for cleaner air?
No. The high efficiency grade is rated with a general purpose stage ahead of it, and without one it takes the full oil and water load. Both Parker and Atlas Copco state that their high efficiency grade must follow the general purpose grade.

What does ppm w/w mean on a Hankison filter?
Parts per million by weight, tested to the CAGI ADF400 standard at a 100 °F inlet. It is not the same unit as the mg/m³ figure European makers use, so compare grades by their position in the row and their ISO 8573-1 class rather than by the raw number.

Do carbon elements show a pressure drop when they are used up?
Do not wait for one. Walker does not fit a differential pressure indicator to its AC carbon filters at all, and the makers give a time instead: at least every six months for Walker AC and a 1,000 hour design life for Hankison grade 1.

BACK TO TOP
Chat directly with MikeThe founder