Atlas Copco 00466884 is the loading solenoid valve for Atlas Copco GA11 air compressors. This aftermarket valve has the same ports, mounting and coil connector as the original, so it fits where the old one came off.
Technical properties & cross references
Specifications
| Part Type |
Load / unload solenoid valve |
| Sold as |
1 piece |
| Condition |
New, aftermarket |
| Stat. HS-Code |
848180 |
| Country of Manufacture |
China |
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| stopsolenoid.com |
USD 117.20 |
27 Nov 2026 |
| eBay (5 aftermarket sellers) |
USD 361.81 to 388.55 |
27 Nov 2026 |
| fridayparts.com |
USD 512.40 |
27 Nov 2026 |
| Fab Heavy Parts |
USD 546.56 |
27 Nov 2026 |
| Spare Part Mart |
USD 99.06 |
Today |
Our price of USD 99.06 is 15% to 82% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
What it does
The solenoid valve switches the compressor between load and unload by opening or closing a control air line when the controller energises its coil.
Signs it has failed
The compressor will not load, will not unload, short cycles, blows off through the intake, or the coil is burnt, open circuit or hot to the touch.
Fitting tips
Isolate the power and release all air pressure first. Check the coil voltage against the controller, fit new seals on the ports, and confirm the compressor loads and unloads cleanly before leaving it running.
Frequently asked questions
Will it replace my original part?
Yes, it is a direct replacement for the original with the same fitting.
How often should I replace it?
There is no fixed interval. It is changed when it fails, and many fail from water in the plug or chafed wiring rather than wear.
What are the signs the solenoid valve needs replacing?
A fault code for this circuit, readings that jump or stay fixed, or a part that does not respond with power at the plug.
Should I grease the connector?
A little dielectric grease keeps water out of the plug on machines that work outside. Make sure the terminals are clean and tight first.
How do I test the old part first?
Read the fault codes, then check the plug and wiring for corrosion or a broken wire. A wiring fault reads the same as a failed solenoid valve.
Is this a genuine Atlas Copco part?
No. It is an aftermarket solenoid valve made to replace the original. It is not made by the original manufacturer; the number only shows what it replaces.