US$25 shipping credit on orders over US$200
Direct from Specialist Manufacturers | 43,000+ Products Available | 30 day money back guarantee
Deltech DFD750 Aftermarket Line Filter Element, Dry Particulate 1 Micron, photo 1
Deltech DFD750 Aftermarket Line Filter Element, Dry Particulate 1 Micron, photo 2
Deltech DFD750 Aftermarket Line Filter Element, Dry Particulate 1 Micron, photo 3

Deltech DFD750 Aftermarket Line Filter Element, Dry Particulate 1 Micron

$169.15 USD
US$25 shipping credit on orders over US$200Comes off your two cheapest shipping options at checkout.
  • SKU: SPM-INF-3036
  • Availability: in stock Many in stock Out of stock In-stock at manufacturer. Please add 5-10 days to shipping time
  • Weight: 3.0 kg (6.61 lb)
Keep a spare: buy 2 and the second one is 5% off ($160.69)
Electronic Timer Condensate Drain Valve for A...: $26.58 $25.26 with this part
Nitrile (NBR) O-Ring Assortment Kit, Metric, ...: $9.78 $9.30 with this part
Members earn 169 points on this order. Join today to earn 200 points off your first order.
Deltech DFD750, direct aftermarket replacement. It is the grade DFD (dry particulate, 1 micron) element for size 750 Deltech compressed air line filters. It measures 118 mm (4-5/8 in) in diameter and 666 mm (26-1/4 in) high and is rated for about 1,558 scfm (2,500 Nm3/h) at 7 bar (100 psi).

This is the dry particulate element that stops desiccant dust and pipe scale down to 1 micron. It is usually fitted after a desiccant dryer, where the air is already dry and only dust needs to be caught. The DFD, PFD, HFD and CFD elements of size 750 share one housing size, so check the letters on the old element before ordering. Every element is checked against the part number before it ships, and every order is covered by our 30 day money back guarantee, worldwide delivery and price beat guarantee. Technical properties & cross references
Specifications
Part Type Compressed air filter element
Replaces Deltech DFD750
Element Size 750
Grade grade DFD (dry particulate, 1 micron)
Filtration Solid particles down to 1 micron (dust filter, no oil removal)
Outside Diameter 118 mm (4-5/8 in)
Height 666 mm (26-1/4 in)
Rated Flow 1,558 scfm (2,500 Nm3/h) at 7 bar (100 psi)
Flow Direction Inside to outside
Max. Operating Pressure 16 bar (232 psi)
Stat. HS-Code 842139
Country of Manufacture China
Cross references
Brand Code
Deltech DFD750
Spare Part Mart SPM-INF-3036

Price beat guarantee

We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:

Seller Price Checked
eBay (2 aftermarket sellers) USD 211.44 to 388.10 7 Oct 2026
Mako-Airtek USD 262.25 2 Nov 2026
Air Compressor Filter Store USD 283.01 2 Nov 2026
Moisture Boss USD 344.08 7 Oct 2026
Compressor Filter Hub USD 385.95 2 Nov 2026
Air Compressor Services USD 1,375.00 7 Oct 2026
Spare Part Mart USD 169.15 Today

Our price of USD 169.15 is 20% to 88% less than these sellers.

Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.

Use cases & applications

Annual element change
Change DFD, PFD and HFD elements at least once a year, or sooner when the pressure drop across the filter reaches about 350 mbar (5 psi). Change CFD carbon elements at least every 6 months.

After a desiccant dryer
The DFD element catches the fine desiccant dust a regenerative dryer sheds, so it does not reach valves, cylinders and instruments.

Workshop and plant air
Line filters sit after the compressor, receiver or dryer to keep water, oil and dirt out of air tools, valves and cylinders.

Frequently asked questions

Will it replace my Deltech DFD750?

Yes, it is a direct replacement for the Deltech DFD750 with the same fitting. If the number is worn off, it measures 118 mm (4-5/8 in) across and 666 mm (26-1/4 in) high.

How often should I replace the Deltech DFD750?

Every 12 months or about 8,000 hours for particulate and coalescing elements, even if the gauge still reads low, because efficiency falls before the element blocks. Activated carbon lasts about 1,000 hours.

What are the signs the element needs replacing?

Pressure drop up by about 0.35 bar from new, the differential gauge in the red, oil or water reaching the tools, or an oil smell in the air after a carbon stage.

Which way round does it go?

The element only seats one way, with its open end pushed onto the spigot in the filter head. Follow the flow arrow on the head when refitting the bowl.

Why is the air wet even with a new element?

An in-line filter removes liquid water and oil aerosols, but not water vapour. If the air is wet downstream, check the dryer and its drains.

Is this a genuine Deltech DFD750?

No. It is an aftermarket element made to replace the Deltech DFD750. It is not made by the original manufacturer; the number only shows what it replaces.

Images and data are used as a guide and are deemed reliable to Spare Part Mart. Product may appear differently (e.g. colour) but will be as per the specs above. All cross references are deemed reliable to our knowledge. We encourage you to double check before ordering.
Buyer's guideIs this the right part for you?

Our verdict

The right element if your Deltech size 750 housing has DFD printed on the old element. It is the dry particulate grade, catching dust and pipe scale down to 1 micron, usually after a desiccant dryer. It does not remove oil.

Good for

  • Deltech size 750 line filters fitted with a DFD element
  • Catching desiccant dust after a desiccant dryer
  • Systems up to about 1,558 scfm (2,500 Nm3/h) at 7 bar and up to 16 bar working pressure

Not the right choice for

  • Removing oil aerosol or oil vapour: that needs a coalescing (PFD, HFD) or carbon (CFD) element
  • Housings other than Deltech size 750
  • Air that is still wet: a dry particulate element belongs after the dryer

Key buying considerations

  • Read the letters on the old element. DFD, PFD, HFD and CFD all fit the same size 750 housing but do different jobs
  • Element size: 118 mm outside diameter, 666 mm tall
  • Flow is inside to outside

In real-world use

In most plants this element sits straight after a desiccant dryer to stop desiccant dust travelling down the line. A rising pressure drop across the housing is the usual sign it needs changing. Swap it like for like with the grade printed on the old element.

How it compares

Against the other size 750 grades: DFD (this one) takes out dry particles to 1 micron; the coalescing grades take out oil aerosol; the carbon grade takes out oil vapour and odour. Choosing the wrong grade still fits the housing, so the letters matter more than the size.

Quick answers

Will a DFD750 remove oil from my air?
No. It is a dry particulate element for dust down to 1 micron. Oil removal needs a coalescing or carbon grade element.

Does it fit any size 750 Deltech housing?
It fits the size 750 housing, which also takes the PFD, HFD and CFD grades. Match the grade letters on your old element.

How big is the element?
118 mm (4-5/8 in) outside diameter and 666 mm (26-1/4 in) tall.