US$25 shipping credit on orders over US$200
Direct from Specialist Manufacturers | 43,000+ Products Available | 30 day money back guarantee
Deltech PFD750 Aftermarket Line Filter Element, General Purpose Coalescing, photo 1
Deltech PFD750 Aftermarket Line Filter Element, General Purpose Coalescing, photo 2
Deltech PFD750 Aftermarket Line Filter Element, General Purpose Coalescing, photo 3

Deltech PFD750 Aftermarket Line Filter Element, General Purpose Coalescing

$171.05 USD
US$25 shipping credit on orders over US$200Comes off your two cheapest shipping options at checkout.
  • SKU: SPM-INF-3037
  • Availability: in stock Many in stock Out of stock In-stock at manufacturer. Please add 5-10 days to shipping time
  • Weight: 3.0 kg (6.61 lb)
Keep a spare: buy 2 and the second one is 5% off ($162.50)
Electronic Timer Condensate Drain Valve for A...: $26.58 $25.26 with this part
Nitrile (NBR) O-Ring Assortment Kit, Metric, ...: $9.78 $9.30 with this part
Members earn 171 points on this order. Join today to earn 200 points off your first order.
Deltech PFD750, direct aftermarket replacement. It is the grade PFD (general purpose coalescing) element for size 750 Deltech compressed air line filters. It measures 118 mm (4-5/8 in) in diameter and 666 mm (26-1/4 in) high and is rated for about 1,558 scfm (2,500 Nm3/h) at 7 bar (100 psi).

This is the general purpose coalescing element that takes water droplets, oil aerosols and dirt out of the air. It is fitted ahead of an HFD element, or on its own where general workshop air quality is enough. The DFD, PFD, HFD and CFD elements of size 750 share one housing size, so check the letters on the old element before ordering. Every element is checked against the part number before it ships, and every order is covered by our 30 day money back guarantee, worldwide delivery and price beat guarantee. Technical properties & cross references
Specifications
Part Type Compressed air filter element
Replaces Deltech PFD750
Element Size 750
Grade grade PFD (general purpose coalescing)
Filtration Oil aerosols, water droplets and particles, ISO 8573-1 class 2 for solids and oil (0.1 micron, 0.1 mg/m3 residual oil, aftermarket maker's data)
Outside Diameter 118 mm (4-5/8 in)
Height 666 mm (26-1/4 in)
Rated Flow 1,558 scfm (2,500 Nm3/h) at 7 bar (100 psi)
Flow Direction Inside to outside
Max. Operating Pressure 16 bar (232 psi)
Stat. HS-Code 842139
Country of Manufacture China
Cross references
Brand Code
Deltech PFD750
Spare Part Mart SPM-INF-3037

Price beat guarantee

We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:

Seller Price Checked
eBay (2 aftermarket sellers) USD 211.44 to 388.27 1 Nov 2026
The Air Market USD 336.53 1 Nov 2026
Moisture Boss USD 337.63 7 Oct 2026
FilterFinder Online USD 419.00 1 Nov 2026
Spare Part Mart USD 171.05 Today

Our price of USD 171.05 is 19% to 59% less than these sellers.

Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.

Use cases & applications

Annual element change
Change DFD, PFD and HFD elements at least once a year, or sooner when the pressure drop across the filter reaches about 350 mbar (5 psi). Change CFD carbon elements at least every 6 months.

Protecting the HFD stage
The PFD element takes out the bulk of the water, oil and dirt so the 0.01 micron HFD element after it lasts its full life.

Workshop and plant air
Line filters sit after the compressor, receiver or dryer to keep water, oil and dirt out of air tools, valves and cylinders.

Frequently asked questions

Will it replace my Deltech PFD750?

Yes, it is a direct replacement for the Deltech PFD750 with the same fitting. If the number is worn off, it measures 118 mm (4-5/8 in) across and 666 mm (26-1/4 in) high.

How often should I replace the Deltech PFD750?

Every 12 months or about 8,000 hours for particulate and coalescing elements, even if the gauge still reads low, because efficiency falls before the element blocks. Activated carbon lasts about 1,000 hours.

What are the signs the element needs replacing?

Pressure drop up by about 0.35 bar from new, the differential gauge in the red, oil or water reaching the tools, or an oil smell in the air after a carbon stage.

How do I read the differential gauge?

Note the reading with the new element fitted and the compressor at full load. Change the element when it rises by about 0.35 bar from that, or the gauge reaches red.

Which way round does it go?

The element only seats one way, with its open end pushed onto the spigot in the filter head. Follow the flow arrow on the head when refitting the bowl.

Is this a genuine Deltech PFD750?

No. It is an aftermarket element made to replace the Deltech PFD750. It is not made by the original manufacturer; the number only shows what it replaces.