Internormen 311448, direct aftermarket replacement. This filter is a direct replacement hydraulic filter element engineered to the original dimensions and ratings for Hydac hydraulic systems. It utilises inorganic microfibre media with a 7 µm filtration rating, ensuring effective contaminant removal under demanding conditions. With a collapse pressure rating of 210 bar and an out-in flow direction, this element maintains reliable performance in high-pressure circuits. Part of a comprehensive cross-reference range covering brands including Epe, Fai Filtri, and Mahle, this filter offers an aftermarket solution without compromising compatibility or quality. Its dimensions, with a total height of 400 mm and outer diameter of 78 mm, ensure a precise fit into your existing housing. By choosing Spare Part Mart, you gain access to cost-effective filtration without sacrificing protection for your hydraulic components.
Technical properties & cross references
Specifications
| Collapse pressure |
210 bar (3046 PSI) |
| Filtration Media |
Inorganic Microfibers 7 µm |
| Media type |
Inorganic Microfibers |
| Filtration Rating |
7 µm |
| Flow direction |
Out-In |
| Total Height |
400 mm (15 3/4") |
| Largest Inner Diameter |
40.5 mm (1 19/32") |
| Largest Outer Diameter |
78 mm (3 1/16") |
| Stat. HS-Code |
84149000 |
| Country of Manufacture |
China |
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| Oxfil |
USD 246.58 |
16 Oct 2026 |
| Cardinal Filters |
USD 259.45 |
12 Oct 2026 |
| Filtration Point |
USD 292.13 |
12 Oct 2026 |
| Hydrafil |
USD 624.95 |
12 Oct 2026 |
| Spare Part Mart |
USD 206.14 |
Today |
Our price of USD 206.14 is 16% to 67% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
High-Pressure Continuous Operation
When hydraulic systems run around the clock at elevated pressures, the 210 bar collapse rating prevents element failure. The robust construction keeps oil clean and machinery productive without unplanned downtime.
Critical Contamination Control
In applications where even minor particle ingress can damage valves and pumps, the 7 µm inorganic microfibre media provides reliable fine filtration. This level of protection extends component life and reduces repair costs.
Fleet Maintenance Efficiency
For workshops servicing multiple Hydac-equipped machines, this filter consolidates inventory across a broad cross-reference. Stocking one aftermarket element covers numerous OEM numbers, simplifying purchasing and reducing shelf space.
Budget-Sensitive Procurement
When maintenance budgets are tight, switching to this direct replacement filter cuts costs without altering fit or performance. The price-beat guarantee ensures you get the best value, while the 30-day money-back promise lets you trial it risk-free.
Frequently asked questions
How do I know this filter fits my Hydac equipment?
Check your existing element against the listed dimensions: 400 mm height, 78 mm outer diameter, and 40.5 mm inner diameter. This filter cross-references multiple OEM part numbers from brands like Epe and Parker Parfit, so verifying your old part number is the most reliable method.
What is the filtration rating and media type?
It uses inorganic microfibre media with a 7 µm absolute filtration rating. This media provides efficient particle retention and a high dirt-holding capacity, suited for hydraulic oil cleanliness requirements.
What are the dimensions and flow direction?
The element measures 400 mm in total height, has a largest outer diameter of 78 mm, and a largest inner diameter of 40.5 mm. Flow direction is out-in, meaning oil passes from the outside to the inside of the element.
Is this a genuine Hydac filter?
No, this filter is an aftermarket replacement built to the original dimensions and ratings. It is not manufactured by Hydac but is designed to directly replace the original element in your housing.
How do I replace the filter element?
First depressurise the hydraulic system and isolate the filter housing. Remove the housing cover, take out the old element, and clean the housing interior. Insert the new element, lubricate the new seal with clean oil, and reassemble. Always follow your equipment manual.