Stauff RE600S25B, direct aftermarket replacement. This filter is a high-performance aftermarket hydraulic filter, built as a direct replacement for the OEM elements found in Hydac equipment and comparable systems. It features a 25-micron wire mesh media that delivers reliable particle removal while allowing full flow rates. The filter has a total height of 921 mm, with outer diameters of 143 mm and inner diameters of 95.5 to 96.5 mm, ensuring a precise fit in compatible housings. Designed with Out-In flow direction and a bypass valve that opens at 3 bar, this element protects hydraulic pumps, valves, and cylinders from abrasive wear. The robust wire mesh construction provides long service life under demanding conditions. Choosing this aftermarket filter reduces operating costs without compromising performance. With cross-references to Epe, Fai Filtri, Fleetguard-ST, Hy-Pro, Hydac, Internormen, Oxfil, ST Separat Tech, and Stauff, it consolidates inventory for maintenance teams managing mixed fleets.
Technical properties & cross references
Specifications
| Filtration Media |
Wire Mesh 25 µm |
| Media type |
Wire Mesh |
| Filtration Rating |
25 µm |
| Flow direction |
Out-In |
| Total Height |
921 mm (36 1/4") |
| Bypass Valve Opening Pressure |
3 bar (44 PSI) |
| Largest Inner Diameter |
96.5 mm (3 13/16") |
| Smallest Inner Diameter |
95.5 mm (3 3/4") |
| Outer Diameter |
143 mm (5 5/8") |
| Largest Outer Diameter |
143.5 mm (5 21/32") |
| Stat. HS-Code |
84149000 |
| Country of Manufacture |
China |
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| Filtration Point |
USD 684.71 |
13 Oct 2026 |
| Cardinal Filters |
USD 701.75 |
13 Oct 2026 |
| Oxfil |
USD 975.10 |
16 Oct 2026 |
| Hydrafil |
USD 1,444.95 |
13 Oct 2026 |
| Spare Part Mart |
USD 561.46 |
Today |
Our price of USD 561.46 is 18% to 61% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
Continuous Duty Hydraulic Systems
In machinery running non-stop, the 25-micron mesh reliably captures contaminants over extended intervals, reducing unscheduled downtime for component repairs.
Dusty and Dirty Environments
Construction or mining equipment exposed to high particulate loads benefit from the durable wire mesh media, which maintains integrity and protects sensitive hydraulics from ingression.
Planned Maintenance Programs
Facilities that replace filters on a schedule appreciate the cost savings of this aftermarket element, allowing more frequent changes within budget without sacrificing filtration quality.
Multi-Brand Fleet Operations
Service providers working on equipment from Hydac and other manufacturers can use this single part number to replace numerous OEM filters, simplifying stock management and reducing ordering errors.
Frequently asked questions
Will this filter fit my Hydac hydraulic system?
This filter is a direct replacement for the filter element used in many Hydac filter housings. Please compare the dimensions (total height 921 mm, outer diameter 143 mm, inner diameters 95.5-96.5 mm) with your existing filter to confirm fitment.
What is the filtration rating of this element?
It uses a wire mesh media rated at 25 microns, suitable for removing fine particulates from hydraulic oil to protect system components.
What are the key dimensions and flow specifications?
The filter has a total height of 921 mm, outer diameter of 143 mm, largest inner diameter 96.5 mm and smallest 95.5 mm. Flow direction is Out-In, and the bypass valve opens at 3 bar.
Is this a genuine OEM part?
No, this is an aftermarket hydraulic filter manufactured to match the specifications and performance of the OEM element. It is not branded as Hydac or any other original manufacturer, but it is a trustworthy direct replacement.
How do I install this filter?
Installation follows standard hydraulic filter replacement procedures. Ensure the housing is clean, lubricate seals, and insert the element noting the Out-In flow path. The integral bypass valve provides protection if the element becomes clogged.