US$25 shipping credit on orders over US$200
Direct from Specialist Manufacturers | 43,000+ Products Available | 30 day money back guarantee
SPM-HYD-2599 Hydraulic Filter
SPM-HYD-2599 Hydraulic Filter
SPM-HYD-2599 Hydraulic Filter, dimension drawing

SPM-HYD-2599 Hydraulic Filter

$180.43 USD
US$25 shipping credit on orders over US$200Comes off your two cheapest shipping options at checkout.
  • SKU: SPM-HYD-2599
  • Availability: in stock Many in stock Out of stock In-stock at manufacturer. Please add 5-10 days to shipping time
  • Weight: 3.0 kg (6.61 lb)
Keep a spare: buy 2 and the second one is 5% off ($171.41)
Nitrile (NBR) O-Ring Assortment Kit, Metric, ...: $9.78 $9.30 with this part
Universal Filter Strap Wrench for Oil, Fuel a...: $9.59 $9.12 with this part
Members earn 180 points on this order. Join today to earn 200 points off your first order.
It is a 10 µm pleated glass fibre filter element with nitrile seals, for Pall 0101 / 2618 series vessel filters and the Hy-Pro equivalents. It measures 153 mm outside diameter, 66.8 mm bore and 912 mm long.

A large 36 in double open end element for multi element filter vessels on lube oil, fuel and process circuits, where several elements sit in one housing. Sold as a single element, shipped worldwide, and covered by our 30 day money back guarantee and price beat guarantee. Technical properties & cross references
Specifications
Part Type Filter element
Replaces Hy-Pro HP101L3612MB / Pall HC0101FKS36H
Filtration Media Pleated glass fibre
Filtration Rating 10 µm, beta 1000 (ISO 16889)
Flow Direction Out-In
Seal Material Nitrile (NBR)
Largest Outer Diameter 153 mm (6 1/32")
Largest Inner Diameter 66.8 mm (2 5/8")
Total Height 912 mm (35 7/8")
Construction Double open end, flat gaskets
Collapse Rating 7 bar (102 psid)
Nominal Length 36 in
Stat. HS-Code 842129
Country of Manufacture China
Compatible equipment
Pall
0101 / 2618 series vessel filters
Hy-Pro
Filters taking the HP101L3612MB element
Measure the old element
OD 153 mmBore 66.8 mmLength 912 mm
Cross references
Brand Code
Hy-Pro HP101L3612MB
Pall HC0101FKS36H
Spare Part Mart SPM-HYD-2599

Price beat guarantee

We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:

Seller Price Checked
Filtration Point USD 219.24 5 Oct 2026
SONA Filtration USD 228.80 5 Oct 2026
Filtrec USD 436.00 5 Oct 2026
Spare Part Mart USD 180.43 Today

Our price of USD 180.43 is 18% to 59% less than these sellers.

Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.

Use cases & applications

Industrial power units
Hy-Pro and Pall elements sit on the power units of presses, machine tools, plastics machines and test rigs. A fresh element keeps valves and pumps at the cleanliness they were designed for.

Turbine and lube oil systems
The same element sizes run on turbine lube and control oil skids, gearbox lubrication and compressor lube systems, where clean oil decides bearing life.

Steel, paper and energy plants
Mill and power plant hydraulic systems use these elements in duplex filters, so the change can happen on line as soon as the indicator trips.

Planned maintenance stock
Sites with several filters on the same element can hold stock for scheduled changes at a lower price than buying OEM every time.

Frequently asked questions

Will it replace my Hy-Pro HP101L3612MB / Pall HC0101FKS36H?

Yes, it is a direct replacement for the Hy-Pro HP101L3612MB / Pall HC0101FKS36H with the same fitting. If the number is worn off, it measures 153 mm (6 1/32") across and 912 mm (35 7/8") high.

How often should I replace the Hy-Pro HP101L3612MB / Pall HC0101FKS36H?

Usually every 500 to 1,000 hours, as in the machine service schedule. The first change on a new or rebuilt machine comes much earlier, often at about 250 hours, to catch the run in debris.

What are the signs the element needs replacing?

The clogging indicator trips, the hydraulics feel slow or noisy when cold, or an oil sample shows high particle counts. Change it after any pump or motor failure as well.

Can I fit a finer grade than the original?

It will catch more, but it also loads faster and raises the pressure drop, so it can sit in bypass more often. Keep to the original grade unless the machine maker gives a finer option.

Should I fill the housing before starting?

Where the housing allows it, yes. Filling it with clean oil cuts the air drawn into the system and the noise at start up. Bleed any air from the high point once it is running.

Is this a genuine Hy-Pro HP101L3612MB / Pall HC0101FKS36H?

No. It is an aftermarket element made to replace the Hy-Pro HP101L3612MB / Pall HC0101FKS36H. It is not made by the original manufacturer; the number only shows what it replaces.

Images and data are used as a guide and are deemed reliable to Spare Part Mart. Product may appear differently (e.g. colour) but will be as per the specs above. All cross references are deemed reliable to our knowledge. We encourage you to double check before ordering.

Related products

BACK TO TOP
Chat directly with MikeThe founder