It is a 10 µm pleated glass fibre filter element with fluorocarbon seals, for Pall HC6300 series filters and the Hy-Pro equivalents. It measures 78.2 mm outside diameter, 40.6 mm bore and 652 mm long.
Unlike most elements it filters from the inside out: oil enters through the bore and leaves through the pleats, the layout of the Pall HC6300 range. Sold as a single element, shipped worldwide, and covered by our
30 day money back guarantee and
price beat guarantee.
Technical properties & cross references
Specifications
| Part Type |
Filter element |
| Replaces |
Hy-Pro HP63L2612MV / Pall HC6300FKS26Z |
| Filtration Media |
Pleated glass fibre |
| Filtration Rating |
10 µm, beta 1000 (ISO 16889) |
| Flow Direction |
In-Out (inside to outside) |
| Seal Material |
Fluorocarbon (FKM / Viton) |
| Largest Outer Diameter |
78.2 mm (3 3/32") |
| Largest Inner Diameter |
40.6 mm (1 19/32") |
| Total Height |
652 mm (25 11/16") |
| Collapse Rating |
10 bar (150 psid) |
| Construction |
Single open end, O-ring seal |
| Nominal Length |
26 in |
| Stat. HS-Code |
842129 |
| Country of Manufacture |
China |
Compatible equipment
Pall
HC6300 series filters
Hy-Pro
Filters taking the HP63L2612MV element
Measure the old element
OD 78.2 mmBore 40.6 mmLength 652 mm
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| SONA Filtration |
USD 66.03 |
5 Oct 2026 |
| Filtration Point |
USD 126.17 |
5 Oct 2026 |
| Filtrec |
USD 312.00 |
5 Oct 2026 |
| Spare Part Mart |
USD 54.21 |
Today |
Our price of USD 54.21 is 18% to 83% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
Industrial power units
Hy-Pro and Pall elements sit on the power units of presses, machine tools, plastics machines and test rigs. A fresh element keeps valves and pumps at the cleanliness they were designed for.
Turbine and lube oil systems
The same element sizes run on turbine lube and control oil skids, gearbox lubrication and compressor lube systems, where clean oil decides bearing life.
Steel, paper and energy plants
Mill and power plant hydraulic systems use these elements in duplex filters, so the change can happen on line as soon as the indicator trips.
Planned maintenance stock
Sites with several filters on the same element can hold stock for scheduled changes at a lower price than buying OEM every time.
Frequently asked questions
Will it replace my Hy-Pro HP63L2612MV / Pall HC6300FKS26Z?
Yes, it is a direct replacement for the Hy-Pro HP63L2612MV / Pall HC6300FKS26Z with the same fitting. If the number is worn off, it measures 78.2 mm (3 3/32") across and 652 mm (25 11/16") high.
How often should I replace the Hy-Pro HP63L2612MV / Pall HC6300FKS26Z?
Usually every 500 to 1,000 hours, as in the machine service schedule. The first change on a new or rebuilt machine comes much earlier, often at about 250 hours, to catch the run in debris.
What are the signs the element needs replacing?
The clogging indicator trips, the hydraulics feel slow or noisy when cold, or an oil sample shows high particle counts. Change it after any pump or motor failure as well.
What does the beta ratio mean?
It is how many particles of the rated size go in for every one that gets through. A beta of 200 at 10 µm, beta 1000 (ISO 16889) means 99.5% of particles at that size are caught.
Should I fill the housing before starting?
Where the housing allows it, yes. Filling it with clean oil cuts the air drawn into the system and the noise at start up. Bleed any air from the high point once it is running.
Is this a genuine Hy-Pro HP63L2612MV / Pall HC6300FKS26Z?
No. It is an aftermarket element made to replace the Hy-Pro HP63L2612MV / Pall HC6300FKS26Z. It is not made by the original manufacturer; the number only shows what it replaces.