It is a 20 to 25 µm pleated glass fibre filter element with nitrile seals, for Pall HC6400 series filters and the Hy-Pro equivalents. It measures 86 mm outside diameter, 49.5 mm bore and 652 mm long.
Unlike most elements it filters from the inside out: oil enters through the bore and leaves through the pleats, the layout of the Pall HC6400 range. Sold as a single element, shipped worldwide, and covered by our
30 day money back guarantee and
price beat guarantee.
Technical properties & cross references
Specifications
| Part Type |
Filter element |
| Replaces |
Hy-Pro HP64L2625MB / Pall HC6400FKT26H |
| Filtration Media |
Pleated glass fibre |
| Filtration Rating |
20 to 25 µm, beta 1000 (ISO 16889) |
| Flow Direction |
In-Out (inside to outside) |
| Seal Material |
Nitrile (NBR) |
| Largest Outer Diameter |
86 mm (3 3/8") |
| Largest Inner Diameter |
49.5 mm (1 15/16") |
| Total Height |
652 mm (25 11/16") |
| Collapse Rating |
10 bar (150 psid) |
| Construction |
Single open end, O-ring seal |
| Nominal Length |
26 in |
| Stat. HS-Code |
842129 |
| Country of Manufacture |
China |
Compatible equipment
Pall
HC6400 series filters
Hy-Pro
Filters taking the HP64L2625MB element
Measure the old element
OD 86 mmBore 49.5 mmLength 652 mm
Price beat guarantee
We check what other aftermarket sellers charge for this same part. Their prices on the date we checked:
| Seller |
Price |
Checked |
| SONA Filtration |
USD 77.00 |
5 Oct 2026 |
| Filtration Point |
USD 134.32 |
5 Oct 2026 |
| Donaldson |
USD 227.00 |
5 Oct 2026 |
| Spare Part Mart |
USD 62.29 |
Today |
Our price of USD 62.29 is 19% to 73% less than these sellers.
Found this part cheaper somewhere else? Send us the listing and we will beat it by 5% under our Price Beat Guarantee. Every order is also covered by our 30 day money back guarantee.
Use cases & applications
Industrial power units
Hy-Pro and Pall elements sit on the power units of presses, machine tools, plastics machines and test rigs. A fresh element keeps valves and pumps at the cleanliness they were designed for.
Turbine and lube oil systems
The same element sizes run on turbine lube and control oil skids, gearbox lubrication and compressor lube systems, where clean oil decides bearing life.
Steel, paper and energy plants
Mill and power plant hydraulic systems use these elements in duplex filters, so the change can happen on line as soon as the indicator trips.
Planned maintenance stock
Sites with several filters on the same element can hold stock for scheduled changes at a lower price than buying OEM every time.
Frequently asked questions
Will it replace my Hy-Pro HP64L2625MB / Pall HC6400FKT26H?
Yes, it is a direct replacement for the Hy-Pro HP64L2625MB / Pall HC6400FKT26H with the same fitting. If the number is worn off, it measures 86 mm (3 3/8") across and 652 mm (25 11/16") high.
How often should I replace the Hy-Pro HP64L2625MB / Pall HC6400FKT26H?
Usually every 500 to 1,000 hours, as in the machine service schedule. The first change on a new or rebuilt machine comes much earlier, often at about 250 hours, to catch the run in debris.
What are the signs the element needs replacing?
The clogging indicator trips, the hydraulics feel slow or noisy when cold, or an oil sample shows high particle counts. Change it after any pump or motor failure as well.
Should I fill the housing before starting?
Where the housing allows it, yes. Filling it with clean oil cuts the air drawn into the system and the noise at start up. Bleed any air from the high point once it is running.
Can I fit a finer grade than the original?
It will catch more, but it also loads faster and raises the pressure drop, so it can sit in bypass more often. Keep to the original grade unless the machine maker gives a finer option.
Is this a genuine Hy-Pro HP64L2625MB / Pall HC6400FKT26H?
No. It is an aftermarket element made to replace the Hy-Pro HP64L2625MB / Pall HC6400FKT26H. It is not made by the original manufacturer; the number only shows what it replaces.